BASIC ADVANTAGES:

  • Ease in providing isolation from grid supply for easy maintenance

  • Ease in transferring incomer power to various areas from one common source incomer

  • Advantageous in providing protection to coupled load by electrical as well as mechanical interlocking system

  • Easy interface with the user: setting parameters by means of keys / soft push buttons with supporting LCD

  • Screen on instruments and providing alarm signals for all trip functions

  • Also provide pre-alarm setting feature for all the trip function

  • Ease in measurement of electrical parameter values

  • Helps in sustaining constant power factor

  • Provides facility for remote operation of load, BMS integration, SCADA Display, etc

Category:

Description

SALIENT FEATURES:

  • Pre-programmed Laser cutting

  • Complete bolted structure

  • Anti-Corrosive surface treatment using 8 Tank treatment and spray painting with oven curing

  • Cubicles and Enclosures fully compartmentalized conforming to Form 3B segregation (IEC: 61439)

  • IP-Protection by Dust and Vermin proof gasketing

  • Easy wire identification with ferrules at both end and marking strips

  • Color Coding Procedure

  • Polycarbonate sheet protection for Live Parts

  • Heat Shrink Sleeved Bus Bar for protection and phase identification

  • Engraved metal name plates

  • Protection Mechanism for monitoring protection to internal or external fault in the circuit

  • Cable entry provision from Top, Bottom and both

  • Inbuilt Communication Module via Modbus or Profibus plug network

  • Local numerical display to monitor setting values measured values and record fault values

  • Cable entry provision from Top, Bottom and both

  • Inbuilt Communication Module via Modbus or Profibus plug network

  • Local numerical display to monitor setting values measured values and record fault values

TYPE TESTED

  • CPRI – Short Circuit Test, 70 kA rms for 1.0 sec, with initial peak of 154 kA on PMCC Panel with ACB

  • CPRI – Temperature Rise Test (up to 45˚C above ambient)

  • CPRI – Ingress Protection (IP-55 ( Category-II)

  • ERDA – Internal Arc Test at 50 kA rms for 0.3 sec

  • Screen on instruments and providing alarm signals for all trip functions

  • Also provide pre-alarm setting feature for all the trip function

  • Ease in measurement of electrical parameter values

  • Helps in sustaining constant power factor

  • Provides facility for remote operation of load, BMS integration, SCADA Display, etc

PANEL SPECIFICATIONS

Voltage 380/415/440V, 50 Hz, 3 Phase, 4 Wire AC System
Construction Type Cubicle Design / Floor Standing
Enclosure Fabricated with 1mm/1.6mm/2mm/2.5mm/3mm CRCA MS sheet
Degree of Protection IP 4X/5X/6X
Busbar Electrolytic Grade Aluminium / Electrolytic Grade Copper / Tinned Electrolytic Grade Copper –provided with colored PVC sleeves & of standard current density (1A/sq.mm for Aluminium & 1.6A/sq.mm for Copper)or customer specified current density
Enclosure Color RAL 7032 Shade (Industrial Standard) / Customer Specified Color